50m 3-Leg Tower - 5m² Loading 160 Km/H
DESCRIPTION
Optimised for cellular telecom applications, this structure is produced with deployment and operation in mind and is capable of supporting 5m² of antenna load whilst remaining within a deflection limit of 0.5° at operational wind speed.
Produced from premium steel members hot dip galvanised equivalent to ASTM A123 (2000) and connected with high grade galvanised bolts, this structure has a design life in excess of 25 years.
Export packed and supplied with holding down bolts, anchor plates and setting template, this product is the quality choice.
LEAD TIME IN WEEKS6 Week(s)
|
Loading | Height | Type | Area | Distributed | Over Top 10m | Antenna Loading | 5m² | Linear | Vertical Run | Feeder Cable & Ladder | 0.40 m²/m |
Design Wind Speeds (3 Second Gust) | Basic Wind Speed | 44.0 m/s | Operational Wind Speed | 31.0 m/s |
Deflection | Less than or Equal to | 0.5° (at Operational Wind Speed) |
Design Parameter | Structure Class | 2 | Exposure Category | C | Topographic Category | 1 |
Material | Standard | Steel Grade | Tensile Strength | Yield Strength | Structural Steel | JIS G 3444 | STK 41 | 402 N/mm² | 235 N/mm² | | JIS G 3101 | SS 400 | 310 N/mm² | 245 N/mm² | Structural Bolts | BS 3692 | 8.8 | 830 N/mm² | 664 N/mm² |
Codes of Practice | ANSI/TIA 222-G : 2005 - Structural Standard for Steel Antenna Tower and Antenna Support Structures | ANSI/AISC 360-05 : 2005 - America Institute of Steel Construction | Galvanization Equivalent to ASTM A123 (2000) |
Features | - Internal Caged Ladder | - Work Platform | - Rest Platform | - Holding Down Bolt Kit | - Setting Template | - Lightning Spike |
|
|
|