7/8" leaky cable radiating type fire retardant jacket
DESCRIPTION
High Performance Leaky Coaxial Cable used for Transmission Lines. Competitively designed for simple installation in the toughest conditions.
LEAD TIME IN WEEKS2 Week(s)
|
Construction Materials | Inner Conductor | Smooth Copper Tube | Dielectric | Physical Foam Polyethylene | Outer Conductor | Corrugated Copper Tube and Slot | Jacket | Black PE or Low Smoke free Fire Retardent |
Physical Dimensions | Inner Conductor Diameter | 9.00 mm | Dielectric Diameter | 22.30 mm | Outer Conductor Diameter | 24.90 mm | Diameter Over Jacket | 27.50 mm |
Mechanical Specifications | Minimum Bending Radius | Single Bending | 90 mm | Repeated Bending | 500 mm | Tensile Strength | 1440 N |
Environmental Specifications | Storage Temperature | -55°C - +85°C | Installation Temperature | -40°C - +60°C | Operation Temperature | -55°C - +85°C |
Electrical Specifications | Capacitance | 76.0pF/m | Impedance | 50 + 1 Ω | Velocity | 88% | Insulation Resistance | 5000 MΩ.km | Jacket Spark | 8 kV | Insulation Voltage | 10 kV | Inner Conductor DC Resistance | 1.20 Ω/km | Outer Conductor DC Resistance | 1.40 Ω/km | VSWR | 0.3 - 0.5 GHz | < 1.15 | 0.8 - 1.0 GHz | < 1.15 | 1.7 - 2.0 GHz | < 1.20 | 2.0 - 2.4 GHz | < 1.20 |
Attenuation (dB/100m) | 75 MHz | 1.20 | 150 MHz | 1.70 | 450 MHz | 3.10 | 800 MHz | 4.30 | 900 MHz | 4.60 | 1800 MHz | 6.90 | 2200 MHz | 7.80 | 2400 MHz | 8.60 |
Coupling Loss (2m) (50%/95%) dB | 75 MHz | 62 / 72 | 150 MHz | 65 / 75 | 450 MHz | 71 / 81 | 800 MHz | 75 / 85 | 900 MHz | 77 / 87 | 1800 MHz | 80 / 89 | 2200 MHz | 80 / 88 | 2400 MHz | 80 / 89 |
Standard Conditions | For Attenuation: VSWR 1.0, Cable Temperature 20 °C (68 °F) | Inner Conductor Temperature 100 °C (212 °F). No solar loading |
Certification | CE Approved | UL Approved |
|
|
|